Water treatment chemicals production base

boiler water treatment chemical

HIXENchem specializes in producing various boiler water agents and has the highest "three-in-one" pressure level in China: dynamic simulation device. Independent developed and produced three series of agents: corrosion scale inhibitors (9701,9501,9801,9901, etc.); oxygen scavengers (7201,7301, etc.); and alkalinity builders (8301,8302,8303, etc.). The pharmaceutical agent has the effects of anti-corrosion and scale prevention, green energy saving, carbon reduction, environmental protection, and maintaining water treatment balance and is widely used in petroleum, chemical industry, coal, power plant, and other industries. We can also provide customized processing services according to the personalized needs of customers.

water treatment for boilers

Our boiler water chemicals mainly include boiler corrosion inhibitors, scale inhibitors, pH adjustment chemicals, oxygen scavengers, etc. Through water treatment chemicals, we can reduce corrosion, scale, foam, and other problems, ensure the normal operation of the boiler, reduce unnecessary downtime, and reduce maintenance costs.

Product Overview

lab

cooling chemical

corrosion Scale inhibitor

Model: BWT9701
Appearance: Transparent colorless liquid
pH: 8.5±1.5
Specific gravity/density: 1.03±0.05 (20℃)
Freezing point: -5℃
Thermal stability: Applicable temperature is 88.0℃~180℃
Freeze-thaw stability: Good

cooling chemical

oxygen scavenger in boiler

Model: BWT7201
Composition: volatile(alkalized) neutralizing amines are completely
soluble in water.
Appearance: Clear and colorless liquid
pH:13.0±1.0
Specific Gravity / Density: 0.95±0.05 (20°C)
Freezing Point: – 18℃
Thermal Stability:Maintain stability in water or steam up to 590℃
Freeze Thaw Stability: Good

lab
water treatment chemicals

cooling chemical

ph adjustment water treatment

Model: BWT8301
Composition: OMA polymer, Film-forming amine, Neutralizing amine
Appearance: Clear or slightly turbid, Colorless or light yellow
Specific Gravity / Density: 1.0±0.05 (20°C)
pH:13.0±1.0
Freezing Point: – 18℃
Thermal Stability: Maintain stability in water or steam up to 590℃
Freeze-Thaw Stability: Good

Solve 4 major problems

Boiler operation issues

Our products can solve the problems of salt accumulation, scaling and corrosion in boilers, stabilize pH values ​​and reduce pipe bursts.

Sewage issues

Reduce the boiler's blowdown rate. Achieve timed blowdown, supporting a 12-hour or 4-hour blowdown cycle.

Operational issues

Reduce manual workload. Replace the addition of trisodium phosphate and sodium hydroxide.

Indicator Problem

Excessive sodium ion content in boiler water, condensate and steam. Excessive silica content in boiler steam.

Water treatment chemicals production base

Our production base

Phone: +86-15154636670

Email: stefan@hixen.co

Water treatment chemicals production base
Water treatment chemicals production base
Water treatment chemicals production base
Water treatment chemicals production base

We warmly invite you to visit our water treatment chemicals production site, where you can see our advanced production lines and meet our dedicated team.

Packaging and storage

Our boiler water treatment chemicals are available in three packaging options. You can select the appropriate specification based on your project requirements. Please also ensure proper chemical storage to maintain safety and effectiveness.
water treatment chemicals packaging

25kg plastic drum

Net weight: 25 kg (6.6 gallons)
Container: Polyethylene container
Dimensions: 30 × 23 × 47 cm
Storage temperature: Room temperature, 5~30℃.

Long-term storage: Please stir well before use to ensure the efficacy of the product.

water treatment chemicals packaging

200kg plastic drum

Net Weight: 200 kg (52.8 gallons)
Container: Polyethylene container

Dimensions: 58 × 58 × 88 cm

Storage temperature: Room temperature, 5~30℃.

Long-term storage: Please stir well before use to ensure the efficacy of the product.

water treatment chemicals packaging

1000kg plastic drum

Net Weight: 1000 kg (264.2 gallons)
Container: Polyethylene container
Dimensions: 120 × 100 × 110 cm

Storage temperature: Room temperature, 5~30℃.

Long-term storage: Please stir well before use to ensure the efficacy of the product.

OEM Solutions in Water Treatment

To ensure the normal operation of the boiler, we can tailor boiler water treatment chemicals according to your water quality and boiler type. We can provide you with personalized solutions to meet your customized needs.

Boiler Water Treatment Chemical

Water Treatment for All Boiler Systems

Our boiler water treatment chemicals are designed to improve the performance and service life of all boiler systems, from steam and hot water boilers to industrial and waste heat boilers. They reduce maintenance costs, prevent corrosion and scale buildup, and ensure smooth, efficient operation.

Why Boiler Water Chemicals Are Necessary?

Poor feed water quality can easily cause scaling and corrosion of boiler heating surface tubes, resulting in uneven heating of tube walls, bursting and leakage of water-cooled walls and superheaters, and ultimately causing abnormal boiler shutdown. The use of boiler water treatment agents can effectively avoid corrosion of boiler heating surfaces, reduce boiler wastewater discharge, and save water resources.
Industrial water treatment

Functions of Boiler Water Chemicals

  • Reduce boiler downtime
  • minimizing maintenance costs
  • maintaining bolier system
  • prevent tube leak
  • Fuel costs
  • reducing boiler scale buildup
  • preventing boiler corrosion

FAQ

  • Scale buildup: Affects heat transfer efficiency and can lead to overheating and failures.
  • Corrosion: Damages the boiler structure and shortens its lifespan.
  • Foaming: Leads to unstable evaporation of water, affecting boiler operation.
  • Tube corrosion: Hazards the boiler piping and may cause serious leaks.
  • Deposition: Affects internal flow and heat exchange efficiency.

Regular maintenance ensures the safe and efficient operation of boilers, reduces failures and downtime, and extends the lifespan of the equipment.

Boiler maintenance typically includes the following four steps:

  • Inspection
  • Cleaning
  • Add Water Treatment chemicals
  • Monitoring

Maintaining the quality of boiler water is important and can be achieved through the following methods:

  1. Regularly test the chemical composition of the water to ensure it is within recommended ranges.
  2. Add appropriate water treatment chemicals to prevent scale, corrosion, and foam formation.

Please contact our customer service team and provide your contact and company information to request a free product sample.